10 changes: 5 additions & 5 deletions packages/modules/devices/solis/solis/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -21,12 +21,12 @@ def __init__(self, component_config: SolisBatSetup) -> None:
def update(self, client: ModbusTcpClient_) -> None:
unit = self.component_config.configuration.modbus_id

power = client.read_holding_registers(33149, ModbusDataType.INT_32, unit=unit) * -1
soc = client.read_holding_registers(31038, ModbusDataType.UINT_16, unit=unit)
power = client.read_input_registers(33149, ModbusDataType.INT_32, unit=unit) * -1
soc = client.read_input_registers(33139, ModbusDataType.UINT_16, unit=unit)
# Geladen in kWh
imported = client.read_holding_registers(33161, ModbusDataType.UINT_32, unit=unit) * 1000
# Entladen in kWh * 0,1
exported = client.read_holding_registers(33165, ModbusDataType.UINT_32, unit=unit) * 100
imported = client.read_input_registers(33161, ModbusDataType.UINT_32, unit=unit) * 1000
# Entladen in kWh
exported = client.read_input_registers(33165, ModbusDataType.UINT_32, unit=unit) * 1000

bat_state = BatState(
power=power,
Expand Down
15 changes: 8 additions & 7 deletions packages/modules/devices/solis/solis/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -19,15 +19,16 @@ def __init__(self, component_config: SolisCounterSetup,

def update(self, client: ModbusTcpClient_):
unit = self.component_config.configuration.modbus_id

register_offset = 30000
if self.version == SolisVersion.inverter:
register_offset = -1
elif self.version == SolisVersion.hybrid:
register_offset = 30000
power = client.read_holding_registers(3263 + register_offset, ModbusDataType.INT_32, unit=unit)
powers = client.read_holding_registers(3257 + register_offset, [ModbusDataType.INT_32]*3, unit=unit)
frequency = client.read_holding_registers(3282 + register_offset, ModbusDataType.UINT_16, unit=unit) / 100
imported = client.read_holding_registers(3283 + register_offset, ModbusDataType.UINT_32, unit=unit) * 10
exported = client.read_holding_registers(3285 + register_offset, ModbusDataType.UINT_32, unit=unit) * 10

power = client.read_input_registers(3263 + register_offset, ModbusDataType.INT_32, unit=unit)
powers = client.read_input_registers(3257 + register_offset, [ModbusDataType.INT_32]*3, unit=unit)
frequency = client.read_input_registers(3282 + register_offset, ModbusDataType.UINT_16, unit=unit) / 100
imported = client.read_input_registers(3283 + register_offset, ModbusDataType.UINT_32, unit=unit) * 10
exported = client.read_input_registers(3285 + register_offset, ModbusDataType.UINT_32, unit=unit) * 10

counter_state = CounterState(
imported=imported,
Expand Down
10 changes: 4 additions & 6 deletions packages/modules/devices/solis/solis/inverter.py
Original file line number Diff line number Diff line change
Expand Up @@ -23,13 +23,11 @@ def update(self, client: ModbusTcpClient_) -> None:
unit = self.component_config.configuration.modbus_id

if self.version == SolisVersion.inverter:
power = client.read_holding_registers(3004, ModbusDataType.UINT_32, unit=unit) * -1
# Unit 1kWh
exported = client.read_holding_registers(3008, ModbusDataType.UINT_32, unit=unit) * 1000
power = client.read_input_registers(3004, ModbusDataType.UINT_32, unit=unit) * -1
exported = client.read_input_registers(3008, ModbusDataType.UINT_32, unit=unit) * 1000
elif self.version == SolisVersion.hybrid:
power = client.read_holding_registers(33057, ModbusDataType.UINT_32, unit=unit) * -1
# Unit 1kWh
exported = client.read_holding_registers(33029, ModbusDataType.UINT_32, unit=unit) * 1000
power = client.read_input_registers(33057, ModbusDataType.UINT_32, unit=unit) * -1
exported = client.read_input_registers(33029, ModbusDataType.UINT_32, unit=unit) * 1000

inverter_state = InverterState(
power=power,
Expand Down