63 changes: 63 additions & 0 deletions drivers/powercom-hid.c
Original file line number Diff line number Diff line change
Expand Up @@ -241,6 +241,66 @@ static info_lkp_t powercom_shutdown_info[] = {
{ 0, NULL, powercom_shutdown_fun, powercom_shutdown_nuf }
};

/* Output section shutdown: uses discrete delay index (1-18) for
* UPS.Output.DelayBeforeShutdown (ReportID 0x23, 8-bit).
* Some Powercom UPS models (e.g. RPT-800AP, BNT-AP series) handle
* shutdown more reliably via the Output section registers than via
* PowerSummary. The native UPSMON PRO software uses these registers.
*
* Delay index table (from protocol spec):
* Index 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
* Value 12s 18s 24s 30s 36s 42s 48s 54s 1m 2m 3m 4m 5m 6m 7m 8m 9m 10m
*/
static double powercom_shutdown_output_nuf(const char *value)
{
const char *s = dstate_getinfo("ups.delay.shutdown");
const char *cfg = getval("offdelay");
int iv;
uint8_t command;

if (value && *value)
iv = atoi(value);
else if (cfg && *cfg)
iv = atoi(cfg);
else if (s && *s)
iv = atoi(s);
else
iv = 60;

/* Convert seconds to discrete delay index per protocol spec */
if (iv <= 12) command = 1;
else if (iv <= 18) command = 2;
else if (iv <= 24) command = 3;
else if (iv <= 30) command = 4;
else if (iv <= 36) command = 5;
else if (iv <= 42) command = 6;
else if (iv <= 48) command = 7;
else if (iv <= 54) command = 8;
else if (iv <= 60) command = 9;
else if (iv <= 120) command = 10;
else if (iv <= 180) command = 11;
else if (iv <= 240) command = 12;
else if (iv <= 300) command = 13;
else if (iv <= 360) command = 14;
else if (iv <= 420) command = 15;
else if (iv <= 480) command = 16;
else if (iv <= 540) command = 17;
else command = 18;

upsdebugx(3, "%s: offdelay=%d -> discrete index=%d (ReportID 0x23)",
__func__, iv, command);

return (double)command;
}

static info_lkp_t powercom_shutdown_output_info[] = {
{ 0, NULL, powercom_shutdown_fun, powercom_shutdown_output_nuf }
};

static info_lkp_t powercom_stayoff_output_info[] = {
{ 0, NULL, NULL, powercom_shutdown_output_nuf }
};

static double powercom_stayoff_nuf(const char *value)
{
const char *s = dstate_getinfo("ups.delay.shutdown");
Expand Down Expand Up @@ -657,6 +717,9 @@ static hid_info_t powercom_hid2nut[] = {
{ "beeper.enable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL },
{ "beeper.disable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "0", HU_TYPE_CMD, NULL },
{ "test.battery.start.quick", 0, 0, "UPS.Battery.Test", NULL, "1", HU_TYPE_CMD, NULL },
/* Output section shutdown (more reliable on RPT/BNT-AP series) */
{ "shutdown.return", 0, 0, "UPS.Output.DelayBeforeShutdown", NULL, NULL, HU_TYPE_CMD, powercom_shutdown_output_info },
{ "shutdown.stayoff", 0, 0, "UPS.Output.DelayBeforeShutdown", NULL, NULL, HU_TYPE_CMD, powercom_stayoff_output_info },
{ "load.on.delay", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, NULL, HU_TYPE_CMD, powercom_startup_info },
{ "shutdown.return", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, NULL, HU_TYPE_CMD, powercom_shutdown_info },
{ "shutdown.stayoff", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, NULL, HU_TYPE_CMD, powercom_stayoff_info },
Expand Down
Loading