171 changes: 136 additions & 35 deletions src/pykmp/constants.py
Original file line number Diff line number Diff line change
Expand Up @@ -16,38 +16,133 @@

# Decimals of each variable in the GetRegister command request/response (CID=0x10)
REGISTERS: Final[Mapping[int, str]] = {
0x003C: "Heat Energy (E1)",
0x0044: "Volume",
0x004A: "Flow",
0x0050: "Current Power",
0x0056: "Temp1",
0x0057: "Temp2",
0x0059: "Tempdiff",
0x0061: "Temp1xm3",
0x006E: "Temp2xm3",
0x0071: "Infoevent",
0x007B: "MaxFlowDate_Y",
0x007C: "MaxFlow_Y",
0x007D: "MinFlowDate_Y",
0x007E: "MinFlow_Y",
0x007F: "MaxPowerDate_Y",
0x0080: "MaxPower_Y",
0x0081: "MinPowerDate_Y",
0x0082: "MinPower_Y",
0x008A: "MaxFlowDate_M",
0x008B: "MaxFlow_M",
0x008C: "MinFlowDate_M",
0x008D: "MinFlow_M",
0x008E: "MaxPowerDate_M",
0x008F: "MaxPower_M",
0x0090: "MinPowerDate_M",
0x0091: "MinPower_M",
0x0092: "AvgTemp1_Y",
0x0093: "AvgTemp2_Y",
0x0095: "AvgTemp1_M",
0x0096: "AvgTemp2_M",
0x010A: "E1HighRes",
0x03EC: "HourCounter",
60: "Heat Energy (E1)",
61: "Inlet Energy E4",
62: "Outlet Energy E5",
63: "Cooling Energy E3",
64: "Tariff TA2",
65: "Tariff TA3",
66: "Tariff limit 2",
67: "Tariff limit 3",
68: "Volume V1",
69: "Volume V2",
72: "Mass M1",
73: "Mass M2",
74: "Flow V1",
75: "Flow V2",
80: "Current Power",
84: "Pulse input A1",
85: "Pulse input B1",
86: "Temp1",
87: "Temp2",
88: "Temp3",
89: "Tempdiff",
91: "Pressure P1",
92: "Pressure P1",
94: "Heat Energy E2",
95: "Tap water energy E6",
96: "Tap water energy E7",
97: "Temp1xm3 E8", # V1 * t1 (inlet)
98: "Target Date",
99: "InfoCode",
104: "Meter number for VB",
110: "Temp2xm3 E9", # V2 * t2 (outlet)
112: "Customer Number 2", # 8 most-significant digits
113: "Infoevent",
114: "Meter number for VA",
122: "Temp4",
123: "MaxFlowDate_Y",
124: "MaxFlow_Y",
125: "MinFlowDate_Y",
126: "MinFlow_Y",
127: "MaxPowerDate_Y",
128: "MaxPower_Y",
129: "MinPowerDate_Y",
130: "MinPower_Y",
138: "MaxFlowDate_M",
139: "MaxFlow_M",
140: "MinFlowDate_M",
141: "MinFlow_M",
142: "MaxPowerDate_M",
143: "MaxPower_M",
144: "MinPowerDate_M",
145: "MinPower_M",
146: "AvgTemp1_Y",
147: "AvgTemp2_Y",
149: "AvgTemp1_M",
150: "AvgTemp2_M",
152: "Program number", # not seen on my meters: ABCCCCCC
153: "Config number 1", # config no. DDDEE
154: "Software Checksum 1",
168: "Config number 2", # config no. FFGGMN
175: "Error hour counter",
178: "Differential energy dE",
179: "Control energy cE",
180: "Differential volume dV",
181: "Control volume cV",
# 183: looks like a meter S/N on our Multical 603
184: "MbusPriAdrMod1",
185: "MbusSekAdrMod1",
218: "MbusPriAdrMod2",
219: "MbusSekAdrMod2",
222: "ConfigChangedEventCount",
224: "Pulse input A2",
225: "Pulse input B2",
229: "T1_average_autoint",
230: "T2_average_autoint",
234: "l/imp. for VA",
235: "l/imp for VB",
239: "Volume V1 hires",
# Undocumented, but it matches the info given by our Multical 603 in the diagnostics display
259: "Nominal Q\N{LATIN SUBSCRIPT SMALL LETTER P}",
266: "E1HighRes",
267: "Cooling energy E3 hires",
346: "Module SW rev",
347: "Customer Number",
348: "Date and Time", # FIXME unkown unit 79, 28591984415535
355: "COP Year",
362: "Tariff TA4",
364: "Heat energy A1", # Heat energy with discount A1, t2 < t5 limit
365: "Heat energy A2", # Heat energy with surcharge A2, t2 > t5 limit
366: "T5 limit",
367: "COP Month",
369: "Info bits",
371: "COP",
372: "Power Input B1",
379: "T1 time average day",
380: "T2 time average day",
381: "T1 time average hour",
382: "T2 time average hour",
383: "Flow V1 max year date",
# 384: something similar?
385: "Power max year date",
# 386: something similar?
387: "Flow V1 max month date",
# 388: something similar?
389: "Power max month date",
# 390: something similar?
398: "T1 actual (one decimal)",
399: "T2 actual (one decimal)",
# Undocumented, but on Multical 603 it works that way
400: "T1-T2 (one decimal)",
404: "Meter Type",
473: "Energy E10",
474: "Energy E11",
477: "T3 time average day",
478: "T3 time average hour",
505: "P1 average day",
506: "P2 average day",
507: "P1 average hour",
508: "P2 average hour",
# Undocumented, but it matches the actual interval on Multical 303
675: "WM-Bus transmission interval",
1001: "Fabrication No",
1002: "Time",
1003: "Date",
1004: "HourCounter",
1005: "Software edition",
1010: "Customer number 1", # 8 least-significant digits
1032: "Operation Mode",
}


Expand All @@ -73,11 +168,11 @@
0x12: "kVAh",
0x13: "MVAh",
0x14: "GVAh",
0x15: "kW",
0x15: "W",
0x16: "kW",
0x17: "MW",
0x18: "GW",
0x19: "kvar",
0x19: "var",
0x1A: "kvar",
0x1B: "Mvar",
0x1C: "Gvar",
Expand All @@ -90,7 +185,7 @@
0x23: "kV",
0x24: "kA",
0x25: "°C",
0x26: "°K",
0x26: "K",
0x27: "l",
0x28: "m³",
0x29: "l/h",
Expand All @@ -117,6 +212,12 @@
0x3E: "days",
0x3F: "RTC-Q",
0x40: "Datetime",
0x55: "%RH",
0x56: "%O\N{SUBSCRIPT TWO}",
0x57: "m/s",
0x58: "kJ/kg",
0x59: "pH",
0x5A: "g/kg",
}


Expand Down