33 changes: 33 additions & 0 deletions docs/apps/schedy/actors/dualthermostat/config.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
# Delta that is added to the temperature value sent to this
# thermostat in order to correct potential inaccuracies of
# the temperature sensor.
#high_delta: 0
#low_delta: 0

# The minimum/maximum temperature the thermostat supports.
# If configured, temperatures outside the supported range are changed
# to the minimum/maximum value before they're sent to the thermostat.
# null means there is no limitation.
#high_min_temp: null
#high_max_temp: null
#low_min_temp: null
#low_max_temp: null

# When this is set to something different than "OFF", Schedy will
# rewrite the value OFF into this temperature before sending it to
# the thermostat. You can set it to 4.0 degrees (if your thermostat
# supports this low value) in order to prevent frost-induced damage
# to your heating setup.
# This setting is required when you want to send OFF to thermostats with
# disabled HVAC mode support.
#off_temp: "OFF"

# Set this to false if your thermostat doesn't support HVAC modes.
# Please note that you won't be able to turn it off completely without
# HVAC mode support. Remember to also configure off_temp when you
# disable this feature.
#supports_hvac_modes: true

# These two settings can be used to tweak the names of the HVAC modes.
#hvac_mode_on: "heat_cool"
#hvac_mode_off: "off"
99 changes: 99 additions & 0 deletions docs/apps/schedy/actors/dualthermostat/index.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,99 @@
Dual Thermostat
==========

The ``dualthermostat`` actor is used to control the temperature of climate
entities.

Often, people ask me whether Schedy can be used with their particular
heating setup. I always tend to repeat myself in these situations,
hence I want to explain here what the exact preconditions for using
Schedy for heating control actually are.

1. You need at least one thermostat in each room you want to control.
Such a thermostat must be recognized as a climate entity in Home
Assistant, and setting the target temperature from the Home Assistant
web interface should work reliably. Wall thermostats can be controlled
the same way as radiator thermostats, as long as they fulfill these
conditions as well. If you only have a switchable heater and an
external temperature sensor, have a look at Home Assistant's `Generic
Thermostat platform`_ to build a virtual thermostat first.

2. If your thermostat is used for both heating and cooling, there has
to be an automatic HVAC mode which does heating/cooling based
on the difference between current and set target temperature. Schedy
will only switch the HVAC mode between on and off (exact names
can be configured) and set the target temperature according to the
room's schedule.

.. _`Generic Thermostat platform`: https://home-assistant.io/components/climate.generic_thermostat/

If you are happy with these points and your setup fulfills them, there
should be nothing stopping you from integrating Schedy's great scheduling
capabilities with your home's heating. You can then go on and create a
Schedy configuration with thermostat actors.


Configuration
-------------

.. include:: ../config.rst.inc


Supported Values
----------------

Your schedules must generate tuples of valid temperature values. Those can be
integers (``(18, 20)``), floats (``(19.5, 21.5)``), or a mixture of both (``(18.5, 21)``).

A special value is ``OFF``, which is an object available in the evaluation
environment when using the thermostat actor type. If this object is
returned from an expression, it will turn the thermostats off. The
equivalent for the ``OFF`` object to use when using plain values instead
of expressions is the string ``"OFF"`` (case-insensitive).

.. note::

When working with the ``Add()`` :doc:`postprocessor
<../../schedules/expressions/postprocessors>` and the result is
``OFF``, it will stay ``OFF``, no matter what's being added to it.


Statistical Parameters
----------------------

.. include:: ../statistics-intro.rst.inc


``high_temp_delta``
~~~~~~~~~~~~~~

This parameter measures the difference between the high target and current
temperature for all thermostats in the associated rooms. It can be used
to control a source of heating energy, such as a fuel oven, with Home
Assistant automations.

Options provided because this is a ``TempDeltaParameter``:

* ``off_value``: Specify how to handle thermostats which are turned
off. Specify either the number to assume as the delta or ``null``, which
causes the thermostat to be excluded from statistics collection. The
default value is ``0``.

``low_temp_delta``
~~~~~~~~~~~~~~

This parameter measures the difference between the low target and current
temperature for all thermostats in the associated rooms. It can be used
to control a source of heating energy, such as a compressor, with Home
Assistant automations.

Options provided because this is a ``TempDeltaParameter``:

* ``off_value``: Specify how to handle thermostats which are turned
off. Specify either the number to assume as the delta or ``null``, which
causes the thermostat to be excluded from statistics collection. The
default value is ``0``.

.. include:: ../../statistics/actor-value-collector.rst.inc

.. include:: ../../statistics/min-avg-max-parameter.rst.inc
2 changes: 1 addition & 1 deletion hass_apps/schedy/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -3,4 +3,4 @@
various sub-modules.
"""

__version__ = "0.8.3"
__version__ = "0.8.3_JM"
2 changes: 2 additions & 0 deletions hass_apps/schedy/actor/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,7 @@
from .generic2 import Generic2Actor
from .switch import SwitchActor
from .thermostat import ThermostatActor
from .dualthermostat import DualThermostatActor


__all__ = [
Expand All @@ -19,6 +20,7 @@
"Generic2Actor",
"SwitchActor",
"ThermostatActor",
"DualThermostatActor",
]


Expand Down