ClimateSync

HACS Custom License: MIT

Developed with Plugwise Emma in mind, but universally usable with any Home Assistant climate entity that exposes current_temperature and temperature attributes.

Recovery release 1.2.2

This release is intentionally built from the stable v1.2.1 baseline and only includes the rounding improvements from PR #8 (rounding_direction). Unwanted functionality introduced in newer lines is intentionally excluded from this recovery patch.

ClimateSync is a HACS-ready Home Assistant custom integration that implements delta-based thermostat synchronisation. It reads the heating demand (delta between target and current temperature) from multiple source climate entities (rooms) and drives a single destination thermostat by continuously adjusting its target temperature.

Why delta-based instead of copying the highest setpoint?

Instead of simply syncing the highest source setpoint to the destination, ClimateSync uses the maximum delta (largest gap between target and current temperature across all rooms) and adds it to the destination's own current temperature:

destination_target = destination_current_temperature + delta_max

This approach was designed with the Plugwise Emma in mind. The Emma is connected to the central-heating boiler (CV) over OpenTherm and internally calculates a desired CV water temperature based on its own current delta. By feeding the Emma the home-wide maximum delta on top of its own measured temperature, ClimateSync lets the Emma function as a full OpenTherm controller — it sees the "hardest working" room's demand and adjusts the boiler modulation accordingly.

Even without an Emma, this delta-based method is more accurate than copying setpoints because it accounts for how far the destination already is from equilibrium.


Features

  • Event-driven updates — reacts immediately to temperature changes.
  • Periodic resync (configurable, default 60 s) to recover from missed events.
  • Anti-flap: only sends climate.set_temperature when the change exceeds a configurable threshold (default 0.2 °C).
  • Rate limiting: maximum one service call per 10 seconds (configurable).
  • Rich diagnostic sensors including a sensor.climatesync_status that makes desyncs visible.
  • No controllable entities — all control is internal via climate.set_temperature.

Installation

Via HACS (recommended)

  1. Open HACS → Integrations → ⋮ → Custom repositories.
  2. Add https://github.com/Patrick1610/ClimateSync as an Integration.
  3. Search for ClimateSync and install.
  4. Restart Home Assistant.

Manual

  1. Copy custom_components/climatesync/ to your <config>/custom_components/ directory.
  2. Restart Home Assistant.

Configuration

Navigate to Settings → Devices & Services → Add Integration → ClimateSync.

Step 1 — Source rooms

Select one or more climate entities that represent the rooms whose heating demand should be tracked. Each selected entity must expose current_temperature and temperature attributes.

Step 2 — Destination & basic settings

Field Default Description
Destination climate entity The thermostat that ClimateSync will control.
Idle temperature 5.0 °C Target temperature sent to the destination when no room has a positive delta (all rooms are at or above their target).
Maximum setpoint 35.0 °C Hard ceiling for the destination setpoint.
Rounding mode 1 decimal Step size used for the computed setpoint.
Rounding direction nearest Whether the computed setpoint is rounded down, normally, or up within the selected rounding mode.

Options Flow — reconfigure everything via the settings gear

After setup, open the integration → Configure (⚙ gear icon) to get the same 2-step wizard again. You can change:

  • Step 1: add or remove source rooms
  • Step 2: change the destination thermostat, idle temperature, maximum setpoint, rounding mode, rounding direction, and advanced options:
Option Default Description
Destination thermostat Change which thermostat is controlled.
Idle temperature 5.0 °C Temperature sent when no room needs heating.
Maximum setpoint 35.0 °C Hard ceiling for the destination setpoint.
Rounding mode 1 decimal Step size used for setpoints.
Rounding direction nearest floor, nearest, or ceiling rounding within the selected mode.
Resync interval 60 s How often ClimateSync checks even without state changes.
Minimum change threshold 0.2 °C Only send a new setpoint if the change exceeds this.
Minimum send interval 10 s At most one service call per this many seconds.

Algorithm

For each source climate entity (room):
    current = current_temperature attribute
    target  = temperature attribute
    delta   = max(target - current, 0)
              (if either attribute is missing/unavailable → delta = 0)

delta_max = max(all room deltas)

If delta_max <= 0:
    setpoint_raw = idle_temperature        # No room needs heating
Else:
    setpoint_raw = destination_current_temperature + delta_max
    # The destination target is set to its own current temperature
    # plus the largest demand across all source rooms. This means the
    # destination "feels" the same heating gap as the hardest-working
    # room, which is critical for OpenTherm controllers like the
    # Plugwise Emma that modulate boiler output based on their own
    # observed delta.

rounded_setpoint = round_setpoint(setpoint_raw, rounding_mode, rounding_direction)
setpoint_final = min(rounded_setpoint, maximum_setpoint)

If abs(destination_current_target - setpoint_final) > min_change_threshold:
    If time_since_last_call >= min_send_interval:
        climate.set_temperature(destination, setpoint_final)

Rounding mode and direction

The rounding mode determines the step size. The rounding direction determines where the raw setpoint lands within that step size. ClimateSync applies epsilon-safe floor/nearest/ceiling rounding to avoid floating-point edge cases around step boundaries.

nearest is the default and preserves the historical ClimateSync behaviour for existing installations. If an older config entry does not contain rounding_direction, ClimateSync treats it as nearest.

Mode Example input Result
0.5 steps 19.3 19.5
1 decimal 19.33 19.3
2 decimals 19.333 19.33
Direction Behaviour
floor Always round down within the selected mode.
nearest Round to the nearest step, matching the old behaviour.
ceiling Always round up within the selected mode.

Plugwise Emma examples:

Mode + direction Raw setpoint Sent setpoint
0.5 steps + ceiling 19.1 19.5
0.5 steps + ceiling 19.5 19.5
0.5 steps + ceiling 19.6 20.0
0.5 steps + floor 19.1 19.0
0.5 steps + floor 19.9 19.5
1 decimal + ceiling 19.11 19.2
1 decimal + floor 19.19 19.1

For Plugwise Emma, 0.5 steps can be useful because Emma commonly accepts half-degree setpoints. Combining 0.5 steps with ceiling can help when small RoomMind deltas would otherwise disappear through normal rounding, for example a raw setpoint of 19.1 becoming 19.5 instead of 19.0.


Entities

All entities are attached to a ClimateSync device. Sensors (setpoint, deltas, destination target) are regular entities; the status sensor is classified as diagnostic.

Sensors

Computed setpoint — sensor.climatesync_1_destination_setpoint

Attribute Description
destination_entity_id The controlled thermostat
destination_current_temperature Current measured temperature at destination
destination_current_target Current target temperature at destination
delta_max Max delta used for this computation
rounding_mode Active rounding mode
rounding_direction Active rounding direction
raw_setpoint Unrounded destination_current_temperature + delta_max, or idle temperature when no room needs heating
rounded_setpoint Raw setpoint after rounding mode and rounding direction
final_setpoint Final setpoint after rounding and maximum-setpoint clamp
idle_temperature Configured idle temperature

State: the final setpoint that ClimateSync wants to apply (destination_current_temperature + delta_max, rounded and capped by maximum setpoint).

Max delta — sensor.climatesync_2_delta_max

Attribute Description
room_deltas Map of {entity_id: delta} for all rooms
leading_room Entity id of the room with the highest delta

State: the maximum delta across all rooms.

Per-room delta sensors — sensor.climatesync_delta_<slug>

One sensor per source climate entity.

Attribute Description
source_entity_id The climate entity this sensor tracks
current_temperature Last known current temperature
target_temperature Last known target temperature
raw_delta target - current (may be negative)

State: max(raw_delta, 0) — the effective heating demand for this room.

Destination current target — sensor.climatesync_destination_current_target

Shows the destination thermostat's actual current target temperature in real time, making it easy to compare against the computed setpoint without switching to the destination device.

Attribute Description
destination_entity_id The controlled thermostat
destination_current_temperature Current measured temperature at destination

State: the destination's current temperature attribute (its active target).

Diagnostic

Status — sensor.climatesync_status (most important)

States:

State Meaning
ok Everything is in sync, no issues.
rate_limited A setpoint update was suppressed because the last call was too recent.
destination_unavailable The destination climate entity is unavailable or unknown.
missing_source_data One or more source entities have missing/unavailable temperature attributes. The integration continues with delta = 0 for those rooms.
apply_failed The climate.set_temperature service call threw an exception. Check last_error.
mismatch The destination's actual target deviates from the desired setpoint beyond the threshold. ClimateSync will attempt to correct this on the next cycle.

Attributes:

Attribute Description
last_update_time ISO timestamp of the last evaluation
last_service_call_time ISO timestamp of the last climate.set_temperature call
last_desired_setpoint What ClimateSync computed as the ideal setpoint
last_applied_setpoint What was last actually sent to the destination
current_destination_target The destination's actual temperature attribute right now
rounding_mode Active rounding mode
rounding_direction Active rounding direction
raw_setpoint Last unrounded setpoint
rounded_setpoint Last rounded setpoint before maximum-setpoint clamp
final_setpoint Last final setpoint after rounding and clamp
mismatch_seconds How long (seconds) the desired and actual setpoint have been diverging
mismatch_since ISO timestamp of when the mismatch started (null when in sync)
resync_count Number of periodic resyncs since startup
apply_attempts Total service call attempts since startup
apply_failures Total service call failures since startup
evaluation_count Total evaluation cycles since startup
skipped_anti_flap Times a setpoint update was skipped because the change was within the threshold
skipped_rate_limit Times a setpoint update was skipped due to rate limiting
last_error Last exception message, if any

Troubleshooting

Destination is not accepting the setpoint

Some thermostats (e.g. Plugwise Emma) only accept specific temperature steps. Use the 0.5 steps rounding mode in that case. If small RoomMind deltas are rounded away, use Rounding direction = ceiling so a raw setpoint such as 19.1 is sent as 19.5 instead of 19.0.

mismatch_seconds keeps growing

An external automation or the user may be overriding the destination's target. ClimateSync will keep trying to reapply on every evaluation cycle and resync. Check if another integration or automation is fighting over the thermostat.

rate_limited appears frequently

The source rooms are changing temperature very rapidly. Increase min_send_interval in the Options Flow to reduce chatter.

missing_source_data

One or more source climate entities are offline or do not expose current_temperature / temperature attributes. ClimateSync treats those rooms as delta = 0 and continues.

destination_unavailable

The destination thermostat is offline. No service calls are made. ClimateSync will recover automatically once the entity becomes available again.

apply_failed

Check last_error in the sensor.climatesync_status attributes. Most likely the climate entity does not support the climate.set_temperature service or the entity id is wrong.


Compatibility

ClimateSync uses only the standard climate.set_temperature service and reads standard climate entity attributes (current_temperature, temperature). It works with any climate integration that follows the standard HA climate platform contract, including but not limited to:

  • Plugwise Emma / Smile
  • Generic Thermostat
  • ESPHome climate components
  • Z-Wave thermostats
  • Zigbee thermostats (ZHA / Zigbee2MQTT)
  • Google Nest (via the Nest integration)

License

MIT — see LICENSE.