HydraBus Plugin

A C++ shared-library plugin that exposes the HydraBus multi-protocol hardware interface through a unified command dispatcher. The plugin covers all protocol modes supported by the HydraHAL library: SPI, I2C, UART, 1-Wire, Raw-Wire, SWD, Smartcard, NFC, MMC, and SDIO.

Version: 1.0.0.0


Table of Contents

  1. Overview
  2. Project Structure
  3. Architecture
  4. Building
  5. Command Reference
  6. Script Files
  7. AUX GPIO Control (aux)
  8. Fault-Tolerant and Privileged Modes
  9. Error Handling and Return Values

Overview

The plugin loads as a dynamic shared library (.so / .dll). The host application calls the exported C entry points pluginEntry() / pluginExit() to create and destroy the plugin object. Once loaded, the host passes configuration settings (serial port, baud rate, timeouts, artefacts path…) via setParams(), optionally calls doInit() to open the UART connection, and then calls doDispatch() for every command it wants to execute.

All commands follow the pattern:

<PLUGIN>.<COMMAND> [subcommand] [arguments]

For example:

HYDRABUS.MODE  spi
HYDRABUS.SPI   speed 10MHz
HYDRABUS.SPI   cfg   polarity=0 phase=1
HYDRABUS.SPI   cs    en
HYDRABUS.SPI   wrrd  9F:3
HYDRABUS.SPI   cs    dis
HYDRABUS.MODE  bbio

Project Structure

hydrabus_plugin/
├── CMakeLists.txt                  # Build definition (shared library, C++20)
├── inc/
│   ├── hydrabus_plugin.hpp         # Main class definition + command tables
│   ├── hydrabus_generic.hpp        # Generic template helpers (dispatch, write, speed, script)
│   └── private/
│       ├── mode_config.hpp         # MODE_COMMANDS_CONFIG_TABLE
│       ├── spi_config.hpp          # SPI command + speed tables
│       ├── i2c_config.hpp          # I2C command + speed tables
│       └── protocol_configs.hpp    # UART, OneWire, RawWire, SWD, Smartcard, NFC, MMC, SDIO tables
└── src/
    ├── hydrabus_plugin.cpp         # Entry points, init/cleanup, INFO, MODE, setParams
    ├── hydrabus_spi.cpp            # SPI sub-commands + SPI_COMMANDS/SPEED config tables
    ├── hydrabus_i2c.cpp            # I2C sub-commands + I2C_COMMANDS/SPEED config tables
    ├── hydrabus_uart.cpp           # UART sub-commands + UART_COMMANDS config table
    ├── hydrabus_onewire.cpp        # 1-Wire sub-commands + ONEWIRE_COMMANDS config table
    ├── hydrabus_rawwire.cpp        # Raw-Wire sub-commands + RAWWIRE_COMMANDS/SPEED config tables
    ├── hydrabus_swd.cpp            # SWD sub-commands + SWD_COMMANDS config table
    ├── hydrabus_smartcard.cpp      # Smartcard sub-commands + SMARTCARD_COMMANDS config table
    ├── hydrabus_nfc.cpp            # NFC sub-commands + NFC_COMMANDS config table
    ├── hydrabus_mmc.cpp            # MMC sub-commands + MMC_COMMANDS config table
    └── hydrabus_sdio.cpp           # SDIO sub-commands + SDIO_COMMANDS config table

Each protocol lives in its own .cpp file, which also defines its own command/speed configuration tables using X-macro patterns.


Architecture

Plugin Lifecycle

pluginEntry()           → creates HydrabusPlugin instance
  setParams()           → loads INI values (port, baud rate, timeouts, artefacts path...)
  doInit()              → opens the UART connection to the HydraBus hardware
  doEnable()            → enables real execution (without this, commands validate args only)
  doDispatch(cmd, args) → routes a command string to the correct handler
  doCleanup()           → tears down active protocol, closes the UART port
pluginExit(ptr)         → deletes the HydrabusPlugin instance

doEnable() controls a "dry-run / validation" mode: when not enabled, every command validates its arguments and returns true without touching the hardware. This allows test frameworks to verify command syntax before the device is connected.

Command Dispatch Model

Commands are stored in two layers of std::map:

  1. Top-level map (m_mapCmds): associates a command name (INFO, MODE, SPI, I2C, …) with a member-function pointer.
  2. Module-level maps (m_mapCmds_SPI, m_mapCmds_I2C, …): each protocol module owns its own map associating sub-command names (cfg, speed, write, read, …) with handler pointers.

A meta-map (m_mapCommandsMaps) maps the module name string to its sub-map, allowing the generic dispatcher to locate any sub-command dynamically.

The registration is driven entirely by X-macros defined in the *_config.hpp headers:

// In spi_config.hpp  (simplified):
#define SPI_COMMANDS_CONFIG_TABLE  \
SPI_CMD_RECORD( cfg   )            \
SPI_CMD_RECORD( speed )            \
SPI_CMD_RECORD( cs    )            \
...

// In the constructor (hydrabus_plugin.hpp):
#define SPI_CMD_RECORD(a) \
    m_mapCmds_SPI.insert({#a, &HydrabusPlugin::m_handle_spi_##a});
SPI_COMMANDS_CONFIG_TABLE
#undef SPI_CMD_RECORD

Adding a new sub-command only requires adding one line to the config table and implementing the handler function—no other registration code is needed.

Generic Template Helpers

hydrabus_generic.hpp provides stateless template functions used by all protocol modules:

Template function Purpose
generic_module_dispatch<T>() Splits "subcmd args" and routes to the module map
generic_module_set_speed<T>() Looks up a speed label in the module speed map and calls setModuleSpeed()
generic_write_data<T>() Unhexlifies a hex string and calls a protocol-specific bulk-write callback
generic_write_read_data<T>() Parses "HEXDATA:rdlen" and calls a protocol-specific wrrd callback
generic_write_read_file<T>() Reads write data from a binary file in chunks and streams results
generic_execute_script<T>() Opens a script file from ARTEFACTS_PATH and runs it via CommScriptClient
generic_module_list_commands<T>() Logs all registered sub-command names (used by help)

INI Configuration Keys

The following keys are read from the host configuration/INI file:

Key Type Description
UART_PORT string Serial port path (e.g., /dev/ttyUSB0, COM3)
BAUDRATE uint32 Baud rate for the host↔HydraBus UART
READ_TIMEOUT uint32 Per-byte read timeout in milliseconds
WRITE_TIMEOUT uint32 Per-byte write timeout in milliseconds
READ_BUF_SIZE uint32 Receive buffer size for script execution
SCRIPT_DELAY uint32 Inter-command delay in milliseconds during script execution
ARTEFACTS_PATH string Base directory for script and binary data files

Building

The plugin is built as a CMake shared library targeting C++20. It links against several utility libraries (uSharedConfig, uIPlugin, uPluginOps, uICoreScript, uCommScriptClient, uUart, uUtils…) and the HydraHAL protocol library, which must all be available in the CMake build tree.

mkdir build && cd build
cmake ..
make hydrabus_plugin

The output is libhydrabus_plugin.so (Linux) or hydrabus_plugin.dll (Windows).


Command Reference

INFO

Prints version information, the active port/baud configuration, and a complete usage summary of all supported commands directly to the logger. This command takes no arguments and works even if doInit() failed (i.e., no hardware is required).

HYDRABUS.INFO

Example output (abbreviated):

HYDRABUS   | Vers: 1.0.0.0
HYDRABUS   | Description: HydraBus multi-protocol interface (SPI/I2C/UART/1-Wire/RawWire/SWD/Smartcard/NFC/MMC/SDIO)
HYDRABUS   |   Port: /dev/ttyUSB0  Baud: 115200
...

MODE

Switch the HydraBus into a specific protocol mode. This must be called before any protocol command. Only one protocol is active at a time; switching modes tears down the previous protocol instance. The mode manager enters BBIO first, then constructs the HydraHAL protocol object.

HYDRABUS.MODE <mode>

Sub-commands

Sub-command Mode byte Repetitions Expected response Description
bbio 0x00 ×20 BBIO1 Enter raw bitbang mode / exit current protocol
spi 0x01 ×1 SPI1 Enter SPI mode
i2c 0x02 ×1 I2C1 Enter I2C mode
uart 0x03 ×1 ART1 Enter UART mode
onewire 0x04 ×1 1W01 Enter 1-Wire mode
rawwire 0x05 ×1 RAW1 Enter Raw-Wire mode
smartcard 0x0B ×1 CRD1 Enter ISO 7816 Smartcard mode
nfc 0x0C ×1 NFC1 Enter NFC reader mode
mmc 0x0D ×1 MMC1 Enter MMC/eMMC mode
sdio 0x0E ×1 SDI1 Enter SDIO mode
swd 0x05 ×1 RAW1 Enter ARM SWD mode (via Raw-Wire transport)

Examples

# Enter SPI mode before any SPI commands
HYDRABUS.MODE spi

# Enter I2C mode
HYDRABUS.MODE i2c

# Enter 1-Wire mode
HYDRABUS.MODE onewire

# Enter ARM SWD mode
HYDRABUS.MODE swd

# Enter NFC reader mode
HYDRABUS.MODE nfc

# Return to BBIO idle (exit current protocol)
HYDRABUS.MODE bbio

SPI

Full-duplex SPI bus interface. Prerequisite: HYDRABUS.MODE spi

HYDRABUS.SPI <subcommand> <args>

SPI · cfg — Configure SPI bus settings

Sets clock polarity, phase, and the hardware device index. The configuration is applied via key=value pairs; only the keys present in the argument are modified.

HYDRABUS.SPI cfg [polarity=0|1] [phase=0|1] [device=0|1]
Key Values Description
polarity 0 / 1 Clock idle level: 0 = low (CPOL=0), 1 = high (CPOL=1)
phase 0 / 1 Clock phase: 0 = first edge (CPHA=0), 1 = second edge (CPHA=1)
device 0 / 1 Hardware SPI device index
# Standard SPI mode 0 (CPOL=0, CPHA=0)
HYDRABUS.SPI cfg polarity=0 phase=0 device=0

# SPI mode 1 (CPOL=0, CPHA=1)
HYDRABUS.SPI cfg polarity=0 phase=1

# SPI mode 3 (CPOL=1, CPHA=1)
HYDRABUS.SPI cfg polarity=1 phase=1

# Print the current configuration
HYDRABUS.SPI cfg ?

SPI · cs — Chip-select control

HYDRABUS.SPI cs <en|dis>
Argument Effect
en Assert CS → GND (logic low, chip selected)
dis Deassert CS → high (chip deselected)
# Select the target chip
HYDRABUS.SPI cs en

# Deselect the target chip
HYDRABUS.SPI cs dis

SPI · speed — Set clock frequency

HYDRABUS.SPI speed <frequency>

Available presets:

Label Index Frequency
320kHz 0 320 kHz (default)
650kHz 1 650 kHz
1MHz 2 1 MHz
2MHz 3 2 MHz
5MHz 4 5 MHz
10MHz 5 10 MHz
21MHz 6 21 MHz
42MHz 7 42 MHz
HYDRABUS.SPI speed 10MHz
HYDRABUS.SPI speed 42MHz
HYDRABUS.SPI speed 320kHz

SPI · write — Bulk SPI transfer (1–16 bytes)

Full-duplex transfer: sends the given bytes on MOSI while clocking MISO. The received MISO bytes are printed as a hex dump.

HYDRABUS.SPI write <HEXDATA>
  • HEXDATA is a hex string, 1–16 bytes (2–32 hex characters).
# Send a single byte (e.g., read JEDEC ID command on a flash)
HYDRABUS.SPI write 9F

# Send four bytes
HYDRABUS.SPI write DEADBEEF

# Write a 16-byte block (maximum)
HYDRABUS.SPI write 000102030405060708090A0B0C0D0E0F

SPI · read — Receive bytes

Clocks 0xFF bytes on MOSI to generate the clock signal and captures MISO. The received bytes are printed as a hex dump.

HYDRABUS.SPI read <N>
# Read 4 bytes
HYDRABUS.SPI read 4

# Read 1 byte
HYDRABUS.SPI read 1

SPI · wrrd — Write then read

Sends a write-then-read transaction in a single operation. Write data and read length are separated by a colon.

HYDRABUS.SPI wrrd <HEXDATA>:<rdlen>
  • HEXDATA — hex string for the write phase (can be empty for read-only).
  • rdlen — decimal number of bytes to read back.
# JEDEC ID: send 0x9F, read 3 bytes (manufacturer, type, capacity)
HYDRABUS.SPI wrrd 9F:3

# Status register read (0x05)
HYDRABUS.SPI wrrd 05:1

# Read 256 bytes starting at address 0x000000 (READ command 0x03)
HYDRABUS.SPI wrrd 03000000:256

# Write Enable (0x06) — write only, no read
HYDRABUS.SPI wrrd 06:0

# Read-only (no write bytes)
HYDRABUS.SPI wrrd :4

SPI · wrrdf — Write/read using binary files

Same as wrrd but the write data is loaded from a binary file and the read data is saved to a file, both resolved under ARTEFACTS_PATH.

HYDRABUS.SPI wrrdf <filename>[:<wrchunk>][:<rdchunk>]
# Send the contents of flash_cmd.bin and save the response
HYDRABUS.SPI wrrdf flash_cmd.bin

# With explicit chunk sizes for large files
HYDRABUS.SPI wrrdf program_page.bin:256:256

SPI · script — Run a command script

Executes a text script from ARTEFACTS_PATH via the CommScriptClient engine.

HYDRABUS.SPI script <filename>
HYDRABUS.SPI script read_flash.txt
HYDRABUS.SPI script erase_chip.txt

SPI · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.SPI aux 0 out 1    # set AUX0 as output, drive high
HYDRABUS.SPI aux 1 in       # set AUX1 as input

I2C

I2C bus master. Prerequisite: HYDRABUS.MODE i2c

HYDRABUS.I2C <subcommand> <args>

I2C · cfg — Configure I2C bus settings

HYDRABUS.I2C cfg [pullup=0|1]
Key Values Description
pullup 0 / 1 Enable / disable internal pull-up resistors on SDA and SCL
HYDRABUS.I2C cfg pullup=1   # enable internal pull-ups
HYDRABUS.I2C cfg ?          # print current cfg

I2C · speed — Set clock speed

HYDRABUS.I2C speed <frequency>
Label Index Frequency
50kHz 0 ~50 kHz
100kHz 1 ~100 kHz (standard)
400kHz 2 ~400 kHz (fast mode)
1MHz 3 ~1 MHz (fast-mode plus)
HYDRABUS.I2C speed 100kHz
HYDRABUS.I2C speed 400kHz

I2C · bit — Send bus control sequences

Sends individual I2C framing signals. Use this for manual transaction construction when wrrd is not sufficient.

HYDRABUS.I2C bit <start|stop|ack|nack>
Argument Description
start Assert START condition (SDA high→low while SCL high)
stop Assert STOP condition (SDA low→high while SCL high)
ack Clock out ACK bit (SDA low)
nack Clock out NACK bit (SDA high)
# Manually build a read transaction for a device at 0x50
HYDRABUS.I2C bit start
HYDRABUS.I2C write A1         # address 0x50 with R/W=1
HYDRABUS.I2C read 1
HYDRABUS.I2C bit nack
HYDRABUS.I2C bit stop

I2C · write — Bulk I2C write (1–16 bytes)

Sends up to 16 bytes. ACK/NACK status is reported for each byte.

HYDRABUS.I2C write <HEXDATA>
# Write device address 0xA0 (write direction) + register 0x10
HYDRABUS.I2C write A010

# Write 4 bytes of data to a register
HYDRABUS.I2C write A0103A7F

I2C · read — Read N bytes

Reads N bytes, sending ACK after each byte except the last (which receives NACK).

HYDRABUS.I2C read <N>
# Read 2 bytes (e.g., a 16-bit sensor register)
HYDRABUS.I2C read 2

# Read 8 bytes
HYDRABUS.I2C read 8

I2C · wrrd — Write then read

Atomic write-then-repeated-START-read transaction (standard I2C register access pattern).

HYDRABUS.I2C wrrd <HEXDATA>:<rdlen>
# Write device address + register, read 2 bytes
# Device 0x48 (TMP102 temperature sensor), register 0x00
HYDRABUS.I2C wrrd 9000:2

# Read 4 bytes from EEPROM at address 0x50, register 0x10
HYDRABUS.I2C wrrd A010:4

# Write only (no read bytes)
HYDRABUS.I2C wrrd A010FF:0

# Read only (no write bytes)
HYDRABUS.I2C wrrd :2

I2C · wrrdf — Write/read using binary files

HYDRABUS.I2C wrrdf <filename>[:<wrchunk>][:<rdchunk>]
HYDRABUS.I2C wrrdf i2c_sequence.bin
HYDRABUS.I2C wrrdf eeprom_write.bin:16:0

I2C · scan — Bus address scan

Probes all 7-bit addresses (0x00–0x7F) and prints the address of every device that responds with an ACK.

HYDRABUS.I2C scan
HYDRABUS.I2C scan
# Example output:
# HB_I2C | Scanning I2C bus...
# HB_I2C | Found device at 0x48
# HB_I2C | Found device at 0x50

I2C · stretch — Configure clock-stretch timeout

Sets the maximum number of cycles the master will wait for a device to release the clock (clock stretching). Set to 0 to disable.

HYDRABUS.I2C stretch <N>
HYDRABUS.I2C stretch 1000   # allow up to 1000 stretch cycles
HYDRABUS.I2C stretch 0      # disable clock stretching

I2C · script — Run a command script

HYDRABUS.I2C script <filename>
HYDRABUS.I2C script eeprom_test.txt
HYDRABUS.I2C script sensor_init.txt

I2C · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.I2C aux 0 out 0    # drive AUX0 low

UART

UART serial interface. Prerequisite: HYDRABUS.MODE uart

HYDRABUS.UART <subcommand> <args>

UART · baud — Set baud rate

Sets an arbitrary baud rate (any value supported by the HydraHAL UART driver).

HYDRABUS.UART baud <N>
HYDRABUS.UART baud 9600
HYDRABUS.UART baud 115200
HYDRABUS.UART baud 921600

UART · parity — Set parity

HYDRABUS.UART parity <none|even|odd>
HYDRABUS.UART parity none
HYDRABUS.UART parity even
HYDRABUS.UART parity odd

UART · echo — Enable/disable RX echo

Controls whether received bytes are echoed back to the host.

HYDRABUS.UART echo <on|off>
# Enable RX echo to monitor incoming data
HYDRABUS.UART echo on

# Disable echo (default state)
HYDRABUS.UART echo off

UART · bridge — Transparent bridge mode

Enters a transparent UART bridge. The HydraBus forwards all data bidirectionally between the host and the UART pins. Exit by pressing the UBTN button on the HydraBus hardware. This call is blocking until UBTN is pressed.

HYDRABUS.UART bridge

UART · write — Bulk UART transmit (1–16 bytes)

Transmits up to 16 bytes.

HYDRABUS.UART write <HEXDATA>
# Send the ASCII string "HELLO"
HYDRABUS.UART write 48454C4C4F

# Send a single byte (e.g., carriage return)
HYDRABUS.UART write 0D

# Send an AT command: "AT\r\n"
HYDRABUS.UART write 41540D0A

UART · read — Receive N bytes

HYDRABUS.UART read <N>
HYDRABUS.UART read 8
HYDRABUS.UART read 1

UART · script — Run a command script

HYDRABUS.UART script <filename>
HYDRABUS.UART script modem_init.txt
HYDRABUS.UART script at_commands.txt

UART · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.UART aux 3 out 1

ONEWIRE

Dallas/Maxim 1-Wire bus master. Prerequisite: HYDRABUS.MODE onewire

HYDRABUS.ONEWIRE <subcommand> <args>

ONEWIRE · cfg — Configure bus settings

HYDRABUS.ONEWIRE cfg [pullup=0|1]
# Enable internal pull-up on DQ (required for standard-power DS18B20)
HYDRABUS.ONEWIRE cfg pullup=1

# Print current configuration
HYDRABUS.ONEWIRE cfg ?

ONEWIRE · reset — Send 1-Wire reset pulse

Sends a 480 µs reset pulse and detects whether any device asserts a presence pulse in response. Returns 1 if devices are present, 0 if no device was detected.

HYDRABUS.ONEWIRE reset

ONEWIRE · write — Bulk 1-Wire write (1–16 bytes)

Sends up to 16 bytes onto the 1-Wire bus.

HYDRABUS.ONEWIRE write <HEXDATA>

Common DS18B20 ROM command bytes:

Hex 1-Wire command
CC SKIP ROM (broadcast)
55 MATCH ROM
F0 SEARCH ROM
33 READ ROM
44 Convert T (start temperature conversion)
BE Read Scratchpad
# Broadcast: skip ROM, then start temperature conversion
HYDRABUS.ONEWIRE write CC44

# Skip ROM + Read Scratchpad (9 bytes follow via read)
HYDRABUS.ONEWIRE write CCBE

# Select a specific device by 64-bit ROM address
HYDRABUS.ONEWIRE write 5528000000AABBCC

ONEWIRE · read — Read N bytes

Reads N bytes from the bus one at a time.

HYDRABUS.ONEWIRE read <N>
# Read the 9-byte DS18B20 scratchpad
HYDRABUS.ONEWIRE read 9

# Read the 8-byte ROM address of a single device
HYDRABUS.ONEWIRE read 8

ONEWIRE · swio — ARM Serial Wire I/O register access

Provides access to the SWIO (ARM CoreSight Serial Wire debug I/O) register bus, which shares the 1-Wire physical interface.

HYDRABUS.ONEWIRE swio init
HYDRABUS.ONEWIRE swio read  <ADDR>
HYDRABUS.ONEWIRE swio write <ADDR> <VALUE>
  • ADDR — 1 hex byte (register address).
  • VALUE — 4 hex bytes, little-endian (32-bit register value).
# Initialise the SWIO bus
HYDRABUS.ONEWIRE swio init

# Read register 0x00
HYDRABUS.ONEWIRE swio read 00

# Write 0x00000050 to register 0x04
HYDRABUS.ONEWIRE swio write 04 50000000

ONEWIRE · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.ONEWIRE aux 0 out 1

RAWWIRE

Bit-bang 2-wire or 3-wire interface. Useful for proprietary serial protocols. Prerequisite: HYDRABUS.MODE rawwire

HYDRABUS.RAWWIRE <subcommand> <args>

RAWWIRE · cfg — Configure bus settings

HYDRABUS.RAWWIRE cfg [polarity=0|1] [wires=2|3] [gpio=0|1]
Key Values Description
polarity 0 / 1 Clock idle level: 0 = low, 1 = high
wires 2 / 3 2-wire (shared MOSI/MISO) or 3-wire (separate MOSI/MISO)
gpio 0 / 1 GPIO mode: 0 = normal, 1 = open-drain
# 2-wire, clock idle low, standard GPIO
HYDRABUS.RAWWIRE cfg polarity=0 wires=2 gpio=0

# 3-wire, clock idle high
HYDRABUS.RAWWIRE cfg polarity=1 wires=3

# Print current configuration
HYDRABUS.RAWWIRE cfg ?

RAWWIRE · speed — Set bit-bang clock speed

HYDRABUS.RAWWIRE speed <frequency>
Label Frequency
5kHz ~5 kHz
50kHz ~50 kHz
100kHz ~100 kHz
1MHz ~1 MHz
HYDRABUS.RAWWIRE speed 100kHz
HYDRABUS.RAWWIRE speed 1MHz

RAWWIRE · sda — Drive SDA/MOSI pin

HYDRABUS.RAWWIRE sda <0|1>
HYDRABUS.RAWWIRE sda 1   # drive SDA high
HYDRABUS.RAWWIRE sda 0   # drive SDA low

RAWWIRE · clk — Control clock line

HYDRABUS.RAWWIRE clk <0|1|tick>
Argument Description
0 Drive CLK permanently low
1 Drive CLK permanently high
tick Generate one clock pulse (low→high→low)
HYDRABUS.RAWWIRE clk tick   # one clock pulse
HYDRABUS.RAWWIRE clk 1      # hold clock high
HYDRABUS.RAWWIRE clk 0      # release clock low

RAWWIRE · bit — Send N bits from a hex byte

Clocks out N bits of a single hex byte, MSB first.

HYDRABUS.RAWWIRE bit <N> <HEXBYTE>
  • N — number of bits to send (1–8).
  • HEXBYTE — 1 hex byte; bits are sent MSB first.
# Send all 8 bits of byte 0xA5
HYDRABUS.RAWWIRE bit 8 A5

# Send only the upper 7 bits of 0xA5
HYDRABUS.RAWWIRE bit 7 A5

# Send 1 bit (MSB of 0x80 = logic 1)
HYDRABUS.RAWWIRE bit 1 80

RAWWIRE · ticks — Generate N bare clock pulses

Sends N clock pulses with no data on SDA.

HYDRABUS.RAWWIRE ticks <N>
  • N — number of clock pulses (1–16).
HYDRABUS.RAWWIRE ticks 8
HYDRABUS.RAWWIRE ticks 16

RAWWIRE · write — Bulk raw-wire write (1–16 bytes)

Sends up to 16 bytes. MISO bytes captured during the transfer are printed.

HYDRABUS.RAWWIRE write <HEXDATA>
HYDRABUS.RAWWIRE write CA
HYDRABUS.RAWWIRE write CAFEBABE
HYDRABUS.RAWWIRE write 0102030405060708

RAWWIRE · read — Read N bytes

HYDRABUS.RAWWIRE read <N>
HYDRABUS.RAWWIRE read 4
HYDRABUS.RAWWIRE read 1

RAWWIRE · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.RAWWIRE aux 1 in

SWD

ARM Serial Wire Debug interface. Prerequisite: HYDRABUS.MODE swd

Note: Call init (or multidrop for multi-drop targets) before issuing any register read/write commands.

HYDRABUS.SWD <subcommand> <args>

SWD · init — Bus initialisation

Sends the JTAG-to-SWD switching sequence and synchronisation clocks to bring the target into SWD mode.

HYDRABUS.SWD init

SWD · multidrop — ADIv6 multi-drop activation

Sends the ADIv6 dormant-to-active sequence to select a specific DP target in a multi-drop SWD configuration.

HYDRABUS.SWD multidrop [addr]
  • addr — optional 32-bit DP address in hex (4 bytes) or decimal. Defaults to 0.
# Activate with default address
HYDRABUS.SWD multidrop

# Activate a specific DP target
HYDRABUS.SWD multidrop 01000000

SWD · read_dp — Read Debug Port register

HYDRABUS.SWD read_dp <addr>
  • addr — hex byte (e.g. 00 = DPIDR, 04 = CTRL/STAT, 08 = SELECT, 0C = RDBUFF).
HYDRABUS.SWD read_dp 00   # read DPIDR
HYDRABUS.SWD read_dp 04   # read CTRL/STAT

Return: DP[0xADDR] = 0xXXXXXXXX


SWD · write_dp — Write Debug Port register

HYDRABUS.SWD write_dp <addr> <value>
  • addr — hex byte.
  • value — hex 32-bit value.
HYDRABUS.SWD write_dp 04 50000000   # power up DP (CTRL/STAT)
HYDRABUS.SWD write_dp 08 000000F0   # select AP 0, bank 0xF

SWD · read_ap — Read Access Port register

HYDRABUS.SWD read_ap <ap_addr> <bank>
  • ap_addr — AP index (hex byte, 0–255).
  • bank — register bank (hex byte).
HYDRABUS.SWD read_ap 00 FC   # read AP 0 IDR (bank 0xFC)
HYDRABUS.SWD read_ap 00 04   # read AP 0 TAR

Return: AP[idx][0xBANK] = 0xXXXXXXXX


SWD · write_ap — Write Access Port register

HYDRABUS.SWD write_ap <ap_addr> <bank> <value>
HYDRABUS.SWD write_ap 00 04 23000002   # configure MEM-AP CSW
HYDRABUS.SWD write_ap 00 08 20000000   # write TAR (target address register)

SWD · scan — Scan all AP slots

Probes all 256 AP indices and prints those with valid (non-zero) IDR values along with their component type information.

HYDRABUS.SWD scan

SWD · abort — Write DP ABORT register

Clears sticky error bits in the DP ABORT register. Useful to recover from a failed transaction.

HYDRABUS.SWD abort [flags]
  • flags — hex byte (default 1F = clear all sticky bits).
HYDRABUS.SWD abort           # clear all sticky bits (default 0x1F)
HYDRABUS.SWD abort 04        # clear STKCMPCLR only

SMARTCARD

ISO 7816 smartcard interface. Prerequisite: HYDRABUS.MODE smartcard

HYDRABUS.SMARTCARD <subcommand> <args>

SMARTCARD · cfg — Configure bus settings

HYDRABUS.SMARTCARD cfg [pullup=0|1]
HYDRABUS.SMARTCARD cfg pullup=1   # enable I/O line pull-up
HYDRABUS.SMARTCARD cfg ?          # print current cfg

SMARTCARD · rst — Drive reset pin

HYDRABUS.SMARTCARD rst <0|1>
HYDRABUS.SMARTCARD rst 0   # assert reset (cold reset)
HYDRABUS.SMARTCARD rst 1   # release reset

SMARTCARD · baud — Set baud rate

HYDRABUS.SMARTCARD baud <N>
HYDRABUS.SMARTCARD baud 9600
HYDRABUS.SMARTCARD baud 38400

SMARTCARD · prescaler — Set clock prescaler

Sets the clock divider (0–255) that divides the card clock frequency.

HYDRABUS.SMARTCARD prescaler <N>
HYDRABUS.SMARTCARD prescaler 10

SMARTCARD · guardtime — Set guard time

Sets the extra guard time between bytes in ETUs (0–255).

HYDRABUS.SMARTCARD guardtime <N>
HYDRABUS.SMARTCARD guardtime 2

SMARTCARD · write — Send APDU bytes

Sends an APDU or raw bytes to the card. Unlike the other protocols, there is no 16-byte limit.

HYDRABUS.SMARTCARD write <HEXDATA>
# SELECT FILE APDU (AID: A0000000031010)
HYDRABUS.SMARTCARD write 00A4040007A0000000031010

# GET RESPONSE
HYDRABUS.SMARTCARD write 00C0000000

SMARTCARD · read — Read N bytes from card

HYDRABUS.SMARTCARD read <N>
# Read 2-byte status word (SW1 SW2)
HYDRABUS.SMARTCARD read 2

SMARTCARD · atr — Retrieve Answer-To-Reset

Triggers a card reset and retrieves the ATR sequence, which identifies the card type and its communication capabilities.

HYDRABUS.SMARTCARD atr

Return: ATR bytes printed as hex dump.


SMARTCARD · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.SMARTCARD aux 0 out 1

NFC

NFC reader interface (ISO 14443-A and ISO 15693). Prerequisite: HYDRABUS.MODE nfc

HYDRABUS.NFC <subcommand> <args>

NFC · mode — Select NFC standard

HYDRABUS.NFC mode <14443a|15693>
HYDRABUS.NFC mode 14443a   # ISO 14443-A (MIFARE, NFC-A tags)
HYDRABUS.NFC mode 15693    # ISO 15693 (vicinity cards)

NFC · rf — Control RF field

HYDRABUS.NFC rf <on|off>
HYDRABUS.NFC rf on    # power up the RF field
HYDRABUS.NFC rf off   # field off (card power down)

NFC · write — Transmit bytes

Transmits bytes to the card. An optional crc token at the end instructs the firmware to append the protocol CRC automatically.

HYDRABUS.NFC write <HEXDATA> [crc]

Return: Card response bytes printed as hex dump.

# Send 2 bytes, no CRC
HYDRABUS.NFC write 6000

# READ BLOCK command with CRC appended by firmware
HYDRABUS.NFC write 3000 crc

NFC · write_bits — Transmit a partial byte

Transmits N bits of a single byte. Used for anti-collision and REQA/WUPA commands that require fewer than 8 bits.

HYDRABUS.NFC write_bits <HEXBYTE> <N>
  • HEXBYTE — 1 hex byte.
  • N — number of bits to send (1–7).

Return: Card response bytes printed as hex dump.

# Send REQA (0x26, 7 bits) to request card presence
HYDRABUS.NFC write_bits 26 7

# Send WUPA (0x52, 7 bits)
HYDRABUS.NFC write_bits 52 7

NFC · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.NFC aux 0 out 1

MMC

eMMC/MMC block device access. Prerequisite: HYDRABUS.MODE mmc

Note: Block size is always 512 bytes.

HYDRABUS.MMC <subcommand> <args>

MMC · cfg — Configure bus width

HYDRABUS.MMC cfg [width=1|4]
HYDRABUS.MMC cfg width=4   # use 4-bit bus
HYDRABUS.MMC cfg width=1   # use 1-bit bus
HYDRABUS.MMC cfg ?         # print current cfg

MMC · cid — Read Card Identification register

Reads the 16-byte CID register, which contains manufacturer ID, product name, serial number, and manufacturing date.

HYDRABUS.MMC cid

MMC · csd — Read Card Specific Data register

Reads the 16-byte CSD register, which describes card capacity, timing, and feature flags.

HYDRABUS.MMC csd

MMC · ext_csd — Read Extended CSD register

Reads the 512-byte EXT_CSD register, which contains extended configuration and status information.

HYDRABUS.MMC ext_csd

MMC · read — Read a 512-byte block

HYDRABUS.MMC read <block_num>
  • block_num — decimal block address.
HYDRABUS.MMC read 0      # read boot sector (block 0)
HYDRABUS.MMC read 2048   # read block 2048

Return: 512-byte block content printed as hex dump.


MMC · write — Write a 512-byte block

HYDRABUS.MMC write <block_num> <HEXDATA>
  • block_num — decimal block address.
  • HEXDATA — exactly 512 bytes (1024 hex characters).
HYDRABUS.MMC write 0 000102030405...   # write 512 bytes to block 0

MMC · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.MMC aux 0 out 1

SDIO

SD card command interface at the raw command level. Prerequisite: HYDRABUS.MODE sdio

Note: cmd_id is a decimal value (0–63). cmd_arg is a 4-byte hex value (e.g. 000001AA). Block size is always 512 bytes.

HYDRABUS.SDIO <subcommand> <args>

SDIO · cfg — Configure bus width and frequency

HYDRABUS.SDIO cfg [width=1|4] [freq=slow|fast]
HYDRABUS.SDIO cfg width=4 freq=fast
HYDRABUS.SDIO cfg ?   # print current cfg

SDIO · send_no — Send command with no response

Sends a command and does not wait for any response.

HYDRABUS.SDIO send_no <cmd_id> <cmd_arg>
HYDRABUS.SDIO send_no 0 00000000   # CMD0 GO_IDLE_STATE

SDIO · send_short — Send command, receive 4-byte response

Sends a command and captures the 4-byte R1, R3, R6, or R7 response.

HYDRABUS.SDIO send_short <cmd_id> <cmd_arg>

Return: 4-byte response printed as hex dump.

HYDRABUS.SDIO send_short 8 000001AA   # CMD8 SEND_IF_COND (check voltage)
HYDRABUS.SDIO send_short 55 00000000  # CMD55 APP_CMD (prefix for ACMD)

SDIO · send_long — Send command, receive 16-byte response

Sends a command and captures the 16-byte R2 response (CID or CSD register content).

HYDRABUS.SDIO send_long <cmd_id> <cmd_arg>

Return: 16-byte response printed as hex dump.

HYDRABUS.SDIO send_long 2 00000000    # CMD2 ALL_SEND_CID
HYDRABUS.SDIO send_long 9 00010000    # CMD9 SEND_CSD for RCA 0x0001

SDIO · read — Send block-read command

Sends a command and captures the 512-byte data block that follows.

HYDRABUS.SDIO read <cmd_id> <cmd_arg>

Return: 512-byte block printed as hex dump.

HYDRABUS.SDIO read 17 00000000   # CMD17 READ_SINGLE_BLOCK at address 0

SDIO · write — Send block-write command

Sends a command followed by a 512-byte data payload.

HYDRABUS.SDIO write <cmd_id> <cmd_arg> <HEXDATA>
  • HEXDATA — exactly 512 bytes (1024 hex characters).
HYDRABUS.SDIO write 24 00000000 000102...   # CMD24 WRITE_BLOCK at address 0

SDIO · aux — AUX GPIO control

See AUX GPIO Control.

HYDRABUS.SDIO aux 0 out 1

Script Files

Script files are plain text files stored under ARTEFACTS_PATH. They are executed by CommScriptClient, which reads the file line by line and sends/receives bytes according to a simple scripting syntax. The SCRIPT_DELAY INI value inserts a delay (in ms) between commands.

The following protocol modules support a script sub-command:

HYDRABUS.SPI    script read_flash.txt
HYDRABUS.I2C    script sensor_probe.txt
HYDRABUS.UART   script at_modem.txt

AUX GPIO Control (aux)

All protocol modules share an identical aux sub-command for controlling the HydraBus AUX GPIO pins (0–3). Each pin can be individually configured as input, output, or open-drain with pull-up.

HYDRABUS.<PROTO> aux <pin_idx> [in|out|pp] [0|1]
Argument Description
pin_idx AUX pin index: 0, 1, 2, or 3
in Set pin as input (high-impedance)
out Set pin as push-pull output
pp Enable pull-up resistor
0 / 1 Drive output low / high
# Set AUX0 as push-pull output and drive it high
HYDRABUS.SPI aux 0 out 1

# Set AUX1 as input (read state)
HYDRABUS.SPI aux 1 in

# Enable pull-up on AUX2
HYDRABUS.I2C aux 2 pp

# Drive AUX3 low
HYDRABUS.UART aux 3 out 0

The aux command is available on all protocol modules (SPI, I2C, UART, ONEWIRE, RAWWIRE, SWD, SMARTCARD, NFC, MMC, SDIO) and operates identically regardless of the active protocol.


Fault-Tolerant and Privileged Modes

  • Fault-tolerant mode (setFaultTolerant() / isFaultTolerant()): when set, the plugin continues execution even after a sub-command returns false. This is useful in test scripts where non-fatal errors should not abort a sequence.
  • Privileged mode (isPrivileged()): always returns false in this plugin. Reserved for future use in the plugin framework.

Error Handling and Return Values

Every handler returns bool:

  • true — command executed successfully (or argument validation passed in disabled mode).
  • false — argument validation failed, an unknown sub-command was given, the protocol returned an unexpected response, the hardware is not in the expected mode, or a file was not found.

Errors and diagnostic messages are emitted via the LOG_PRINT macros at various severity levels (LOG_ERROR, LOG_WARNING, LOG_INFO, LOG_VERBOSE). The host application controls log verbosity through the shared uLogger configuration.

If a handler is called when the plugin is not in the correct protocol mode (e.g., calling HYDRABUS.SPI write before HYDRABUS.MODE spi), the protocol accessor returns nullptr and the handler logs an error and returns false immediately.