Skip to content

GLOWS L3bc - handle OMNI data with missing alpha/proton ratio #98

@jtniehof

Description

@jtniehof

Summary

There may be periods when the OMNI data are available, but do not have a valid alpha/proton ratio. We should proceed with processing L3bc using a default ratio, and flag relevant times.

Requirements

  • Update omni2 validation to allow processing without valid alpha/proton ratio
  • Use 0.04 (4%) as default alpha/proton ratio
  • Add new quality flags variable to L3b, L3c, L3d, L3e
  • Set a quality flag for NOMINAL_ALPHA_PROTON_RATIO if the default is used for any input times
  • Propagate NOMINAL_ALPHA_PROTON_RATIO to L3c, L3d, L3e

Related tickets

No response

Metadata

Metadata

Labels

Data Release 1See - https://lasp.colorado.edu/galaxy/spaces/IMAP/pages/324168272/Public+ReleasesIns: GLOWSRelated to the GLOWS instrumentRelease BlockerNeeds to be addressed before (next) public releaseenhancementNew feature or request