Trying to use n4-standard-* machines. These require hyperdisk-balanced. This is being set in command line via:
--disk-type hyperdisk-balanced however job fails with:
Job gets non-retryable information Batch Error: code - CODE_GCE_INVALID_FIELD_VALUE, description - Invalid value for field 'operation': ''. No zone supports all of the provided instance templates. The following errors detail the failure. [pd-standard, n4-standard-2] features are not compatible for creating instance..