Skip to content

[PWGLF] added nsigma ITS selections in the purity studies for li4. Fixed bug in the nuclei from hypertriton map #22118

[PWGLF] added nsigma ITS selections in the purity studies for li4. Fixed bug in the nuclei from hypertriton map

[PWGLF] added nsigma ITS selections in the purity studies for li4. Fixed bug in the nuclei from hypertriton map #22118

Triggered via pull request December 18, 2025 11:11
Status Failure
Total duration 15s
Artifacts

o2-linter.yml

on: pull_request_target
O2 linter
12s
O2 linter
Fit to window
Zoom out
Zoom in

Annotations

10 errors and 2 notices
[name/configurable]: PWGLF/Tasks/Nuspex/nucleiFromHypertritonMap.cxx#L76
Use lowerCamelCase for names of configurables and use the same name for the struct member as for the JSON string. (Declare the type and names on the same line.)
[name/workflow-file]: PWGLF/Tasks/Nuspex/nucleiFromHypertritonMap.cxx#L1
Name of a workflow file must match the name of the main struct in it (without the PWG prefix). (Class implementation files should be in "Core" directories.)
[magic-number]: PWGLF/Tasks/Nuspex/nucleiFromHypertritonMap.cxx#L243
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
[magic-number]: PWGLF/Tasks/Nuspex/nucleiFromHypertritonMap.cxx#L237
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
[pdg/database]: PWGLF/Tasks/Nuspex/nucleiFromHypertritonMap.cxx#L37
Do not use TDatabasePDG directly. Use o2::constants::physics::Mass... or Service<o2::framework::O2DatabasePDG> instead.
[name/workflow-file]: PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L1
Name of a workflow file must match the name of the main struct in it (without the PWG prefix). (Class implementation files should be in "Core" directories.)
[magic-number]: PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L673
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
[magic-number]: PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L651
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
[magic-number]: PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L483
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
[pdg/database]: PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L52
Do not use TDatabasePDG directly. Use o2::constants::physics::Mass... or Service<o2::framework::O2DatabasePDG> instead.
O2 linter
To tolerate certain issues in a directory, add a line with the test name in "o2linter_config".
O2 linter
Exceptionally, you can disable a test for a line by adding a comment with "o2-linter: disable=" followed by the name of the test and parentheses with a reason for the exception.