[PWGLF] added pt correction for he3 tracked as triton in the purity s… #21952
Triggered via pull request
December 15, 2025 16:47
GiorgioAlbertoLucia
synchronize
#14221
Status
Failure
Total duration
15s
Artifacts
–
Annotations
7 errors and 2 notices
|
O2 linter
Process completed with exit code 1.
|
|
O2 linter result
Issues have been found.
|
|
[name/workflow-file]:
PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L1
Name of a workflow file must match the name of the main struct in it (without the PWG prefix). (Class implementation files should be in "Core" directories.)
|
|
[magic-number]:
PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L672
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
|
|
[magic-number]:
PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L650
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
|
|
[magic-number]:
PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L480
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
|
|
[pdg/database]:
PWGLF/TableProducer/Nuspex/he3HadronFemto.cxx#L52
Do not use TDatabasePDG directly. Use o2::constants::physics::Mass... or Service<o2::framework::O2DatabasePDG> instead.
|
|
O2 linter
To tolerate certain issues in a directory, add a line with the test name in "o2linter_config".
|
|
O2 linter
Exceptionally, you can disable a test for a line by adding a comment with "o2-linter: disable=" followed by the name of the test and parentheses with a reason for the exception.
|