[PWGCF] Update femtoDreamProducerTask.cxx #21239
Annotations
10 errors and 2 notices
|
[name/configurable]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L109
Use lowerCamelCase for names of configurables and use the same name for the struct member as for the JSON string. (Declare the type and names on the same line.)
|
|
[name/configurable]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L108
Use lowerCamelCase for names of configurables and use the same name for the struct member as for the JSON string. (Declare the type and names on the same line.)
|
|
[name/workflow-file]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L1
Name of a workflow file must match the name of the main struct in it (without the PWG prefix). (Class implementation files should be in "Core" directories.)
|
|
[magic-number]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L1124
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
|
|
[magic-number]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L654
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
|
|
[magic-number]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L645
Avoid magic numbers in expressions. Assign the value to a clearly named variable or constant.
|
|
[const-ref-in-for-loop]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L942
Use constant references for non-modified iterators in range-based for loops.
|
|
[const-ref-in-for-loop]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L853
Use constant references for non-modified iterators in range-based for loops.
|
|
[const-ref-in-for-loop]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L774
Use constant references for non-modified iterators in range-based for loops.
|
|
[std-prefix]:
PWGCF/FemtoDream/TableProducer/femtoDreamProducerTask.cxx#L633
Use std:: prefix for names from the std namespace.
|
|
O2 linter
To tolerate certain issues in a directory, add a line with the test name in "o2linter_config".
|
|
O2 linter
Exceptionally, you can disable a test for a line by adding a comment with "o2-linter: disable=" followed by the name of the test and parentheses with a reason for the exception.
|