Skip to content

[PWGLF] QA code for eff calculation #21126

[PWGLF] QA code for eff calculation

[PWGLF] QA code for eff calculation #21126

Triggered via pull request November 26, 2025 14:07
Status Failure
Total duration 15s
Artifacts

o2-linter.yml

on: pull_request_target
O2 linter
11s
O2 linter
Fit to window
Zoom out
Zoom in

Annotations

10 errors and 2 notices
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L179
Workflow name cascadeanalysislightions does not match its file name cascadeAnalysisLightIonsDerivedData.cxx. (Matches cascadeanalysislightions.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L174
Workflow name lambdatwopartpolarization does not match its file name lambdaTwoPartPolarization.cxx. (Matches lambdatwopartpolarization.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L159
Workflow name lambdajetpolarization does not match its file name lambdaJetpolarization.cxx. (Matches lambdajetpolarization.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L77
Workflow name hstrangecorrelation does not match its file name hStrangeCorrelation.cxx. (Matches hstrangecorrelation.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L62
Workflow name vzero-cascade-absorption does not match its file name vzero_cascade_absorption.cxx. (Matches vzeroCascadeAbsorption.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L57
Workflow name xi-lambda-corr-task does not match its file name xiLambdaCorr.cxx. (Matches xiLambdaCorrTask.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L52
Workflow name k0mixedevents does not match its file name k0_mixed_events.cxx. (Matches k0mixedevents.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L32
Workflow name cascadeanalysismc does not match its file name cascadeanalysisMC.cxx. (Matches cascadeanalysismc.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L22
Workflow name lambdakzeroanalysis-mc does not match its file name lambdakzeroanalysisMC.cxx. (Matches lambdakzeroanalysisMc.cxx.)
[name/o2-workflow]: PWGLF/Tasks/Strangeness/CMakeLists.txt#L12
Workflow name hyperon-reco-test does not match its file name hyperon-reco-test.cxx. (Matches hyperonRecoTest.cxx.)
O2 linter
To tolerate certain issues in a directory, add a line with the test name in "o2linter_config".
O2 linter
Exceptionally, you can disable a test for a line by adding a comment with "o2-linter: disable=" followed by the name of the test and parentheses with a reason for the exception.