Skip to content

Commit f880478

Browse files
committed
Geant4: Disable TransportationWithMsc mode
The combined transportation + multiple scattering stepping mode was introduced in Geant4 11.1 and made the default for physics list FTFP_BERT_EMV. For ALICE, this mode does not work as spotted here: https://its.cern.ch/jira/browse/O2-5212 Disabling this mode fixed the issue and restores the behaviour from Geant4 11.0.4
1 parent bb12ce2 commit f880478

File tree

1 file changed

+3
-0
lines changed

1 file changed

+3
-0
lines changed

Detectors/gconfig/g4config.in

Lines changed: 3 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -43,6 +43,9 @@
4343
/mcPhysics/emModel/setRegions EMC_Lead$ EMC_Scintillator$
4444
/mcPhysics/emModel/setParticles e- e+
4545

46+
# combined transportation + Msc mode is currently broken for ALICE (Geant 10.2.0)
47+
/process/em/transportationWithMsc Disabled
48+
4649
#
4750
# Adding extra lines for fixing tracking bias
4851
#

0 commit comments

Comments
 (0)